| NARSTO EPA Supersite (SS) Baltimore, Semicontinuous Elements in Aerosol Sampler (SEAS) Particulate Matter (PM) 25 Metal Cytokines Data |
1 |
LABORATORY, GROUND STATIONS |
AEROSOL COLLECTORS, AAS |
2001-08-27 to 2002-11-27 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Fresno, Aethalometer Multi-Wavelength Carbon Data |
1 |
GROUND STATIONS |
AETHALOMETER |
1999-05-12 to 2007-01-01 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Fresno, Beta Attenuation Monitors (BAM), Particulate Mass Concentration Data |
1 |
GROUND STATIONS |
PARTICLE DETECTORS |
1999-12-04 to 2004-01-01 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Fresno, Elemental Carbon in 2.5 um Aerosol Fraction Data |
1 |
GROUND STATIONS |
AETHALOMETER |
1999-12-17 to 2007-01-01 |
|
|
CSV |
| NARSTO EPA Supersite (SS) Fresno, Particle-bound Polycyclic Aromatic Compound Data |
1 |
GROUND STATIONS |
PAS |
1999-09-30 to 2007-01-01 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Fresno, Particulate Matter (PM) 2.5 Organic and Elemental Carbon Data |
1 |
GROUND STATIONS |
NDIR GAS ANALYZER |
2000-01-13 to 2005-04-01 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Fresno, Particulate Matter (PM) 2.5 Particulate Nitrate and Sulfate Data |
1 |
GROUND STATIONS |
PARTICLE DETECTORS, CHEMILUMINESCENCE, FLUORESCENCE SPECTROSCOPY |
2000-10-12 to 2006-01-01 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Houston, Texas Air Quality Study 2000 (TexAQS2000) Department of Energy (DOE) G-1 Air Chemistry, Aerosol, and Met Data |
1 |
Aircraft |
BAROMETERS, NDIR GAS ANALYZER, TEMPERATURE PROBES, UV OZONE DETECTORS, HPLC, PYRANOMETERS, HYGROMETERS, CHEMILUMINESCENCE, ION CHROMATOGRAPHS, GUST PROBES, FLUOROMETERS, PHOTOMETERS |
2000-08-19 to 2000-09-12 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Houston, Texas Air Quality Study 2000 (TexAQS2000) Particulate Matter (PM) 2.5 Organic Speciation Data |
1 |
GROUND STATIONS |
GC-MS |
2000-08-15 to 2000-09-15 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Houston, Texas Air Quality Study 2000 (TexAQS2000) Size-specific Particulate Matter (PM) Mass Concentration Data |
1 |
GROUND STATIONS |
AEROSOL COLLECTORS |
2000-08-17 to 2000-09-13 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Houston, Texas Air Quality Study 2000 (TexAQS2000) Texas Natural Resource Conservation Commission (TNRCC) continuous ambient monitoring stations (CAMS) Air Quality Data |
1 |
GROUND STATIONS, METEOROLOGICAL STATIONS |
NDIR GAS ANALYZER, UV OZONE DETECTORS, TEOM, PYRANOMETERS, CHEMILUMINESCENCE, FLUORESCENCE SPECTROSCOPY, ANEMOMETERS, THERMISTORS |
2000-08-02 to 2000-09-30 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Los Angeles Aethalometer Elemental Carbon Data |
1 |
GROUND STATIONS |
AETHALOMETER |
2000-09-15 to 2003-10-16 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Los Angeles Harvard/EPA Annular Denuder System (HEADS) Data |
1 |
GROUND STATIONS |
AEROSOL COLLECTORS |
2001-03-14 to 2003-06-11 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Los Angeles Particulate Matter (PM) 2.5-10 Composition and Mass Data |
1 |
GROUND STATIONS |
AEROSOL COLLECTORS |
2000-10-03 to 2003-09-19 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Los Angeles Size-Fractionated Particulate Matter (PM) Composition - micro-orifice uniform deposit impactors (MOUDI) Data |
1 |
GROUND STATIONS |
XRF, AEROSOL COLLECTORS |
2000-10-03 to 2003-09-19 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Los Angeles Tapered-Element Oscillating Microbalance (TEOM) Particulate Matter (PM) 2.5 Mass Concentration Data |
1 |
GROUND STATIONS |
TEOM |
2000-12-19 to 2002-09-03 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) New York Air Chemistry, Particulate Matter, and Meteorological Data |
1 |
GROUND STATIONS |
BAROMETERS, UV OZONE DETECTORS, PYRANOMETERS, HYGROMETERS, CHEMILUMINESCENCE, ION CHROMATOGRAPHS, ANEMOMETERS, THERMISTORS |
2000-01-01 to 2006-01-01 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Pittsburgh Gas Concentration and Particulate matter (PM) Physical Properties Data |
1 |
GROUND STATIONS |
AEROSOL/CLOUD PARTICLE SIZER, FLUORESCENCE SPECTROSCOPY, SMPS |
2001-05-23 to 2002-09-01 |
|
|
ASCII |
| NARSTO EPA Supersite (SS) Pittsburgh Particulate Matter (PM) Composition Data |
1 |
LABORATORY |
SPECTROPHOTOMETERS, ICP-MS, ION CHROMATOGRAPHS |
2001-06-29 to 2002-09-29 |
|
|
ASCII |
| NARSTO EPA_SS_HOUSTON Differential Mobility Analyzer Data |
1 |
GROUND STATIONS |
DIFFERENTIAL MOBILITY ANALYZERS |
2000-08-18 to 2001-11-07 |
|
|
ASCII |
| NARSTO EPA_SS_HOUSTON PM2.5 Nitrate, Sulfate, and Carbon Data |
1 |
GROUND STATIONS |
AEROSOL COLLECTORS, CHEMILUMINESCENCE, IR CO2 ANALYZER |
2000-08-12 to 2002-11-05 |
|
|
ASCII |
| NARSTO EPA_SS_HOUSTON TEXAQS2000 Particulate Matter FTIR Composition |
1 |
GROUND STATIONS |
FOURIER TRANSFORM SPECTROMETERS |
2000-08-05 to 2000-09-13 |
|
|
ASCII |
| NARSTO EPA_SS_HOUSTON TEXAQS2000 Washburn Tunnel Air Quality Monitoring Data |
1 |
LABORATORY, GROUND STATIONS |
FOURIER TRANSFORM SPECTROMETERS, GAS CHROMATOGRAPHS, AEROSOL COLLECTORS, CHEMILUMINESCENCE, ION CHROMATOGRAPHS |
2000-08-29 to 2000-09-01 |
|
|
ASCII |
| NARSTO EPA_SS_LOS_ANGELES Aerodynamic Particle Size Data |
1 |
GROUND STATIONS |
APS |
2000-12-08 to 2001-09-08 |
|
|
ASCII |
| NARSTO EPA_SS_LOS_ANGELES PM2.5 Particulate Carbon |
1 |
GROUND STATIONS |
NDIR GAS ANALYZER |
2002-01-14 to 2002-05-24 |
|
|
ASCII |