Skip to main content

Nitrogen Oxides Data Access and Tools

Access topic-specific data and resources for accessing, visualizing, preparing/manipulating (e.g. subsetting), and analyzing data. Each observation, model, and reanalysis data has unique characteristics that should be considered when evaluating its use.

An asterisk (*) next to an entry indicates that near real-time (NRT) data products are available through NASA's Land, Atmosphere Near real-time Capability for Earth observation (LANCE). While not intended for scientific research, NRT data are good resources for monitoring ongoing or time-critical events. Learn more about the difference between near real-time versus standard products.

Commonly Used Nitrogen Dioxide Data at a Glance

Spatial ResolutionSpatial CoverageTemporal ResolutionTemporal CoverageSpectral ResolutionSatellite/ PlatformName (Instrument, Model, etc.)Observation, Model, or ReanalysisFile Format
0.25°, 13 km x 24 kmGlobal98 min, Daily2004-near present1.0-0.45 nm Full Width and Half Maximum (FWHM)Aura Ozone Monitoring Instrument (OMI)ObservationHDF-EOS5
5.5 km x 3.5 kmGlobal101.5 minutes2021-present270 nm-2.3 µm, 0.55 nmESA Sentinel-5PTROPOspheric Monitoring Instrument (TROPOMI)ObservationnetCDF
2.0 km x 4.75 kmNorth AmericaHourly08/2023 - present0.6 nmIntelsat 40eTropospheric Emissions: Monitoring Pollution (TEMPO)ObservationnetCDF
0.25º x 0.25°Global15 min, HourlyDaily 5-day forecastN/AN/AGEOS-CFModelnetCDF
0.0083° x 0.0083°Near-globalYearly1990-2020N/AN/ALUR ModelnetCDF
Point measurementsGlobalPeriodic flights occurred during each deployment2016-2018VariesAirborne Field CampaignAtmospheric Tomography Mission (ATom) campaign with varying instrumentsObservationnetCDF

Nitrogen Oxides Datasets

Dataset Platforms Instruments Temporal Extent Location Keywords Spatial Extent Data Format
NARSTO EPA Supersite (SS) Atlanta 1999 Air Chemistry, Particulate Matter (PM), and Meteorological Data LABORATORY, GROUND STATIONS, METEOROLOGICAL STATIONS BAROMETERS, NDIR GAS ANALYZER, UV OZONE DETECTORS, TEOM, PYRANOMETERS, HYGROMETERS, CHEMILUMINESCENCE, ION CHROMATOGRAPHS, ANEMOMETERS 1999-07-30 to 1999-09-03 UNITED STATES OF AMERICA, GEORGIA ASCII
NARSTO EPA Supersite (SS) Houston, Texas Air Quality Study 2000 (TexAQS2000) Department of Energy (DOE) G-1 Air Chemistry, Aerosol, and Met Data AIRCRAFT BAROMETERS, NDIR GAS ANALYZER, TEMPERATURE PROBES, UV OZONE DETECTORS, HPLC, PYRANOMETERS, HYGROMETERS, CHEMILUMINESCENCE, ION CHROMATOGRAPHS, GUST PROBES, FLUOROMETERS, PHOTOMETERS 2000-08-19 to 2000-09-12 TEXAS ASCII
NARSTO EPA Supersite (SS) Houston, Texas Air Quality Study 2000 (TexAQS2000) Texas Natural Resource Conservation Commission (TNRCC) continuous ambient monitoring stations (CAMS) Air Quality Data GROUND STATIONS, METEOROLOGICAL STATIONS NDIR GAS ANALYZER, UV OZONE DETECTORS, TEOM, PYRANOMETERS, CHEMILUMINESCENCE, FLUORESCENCE SPECTROSCOPY, ANEMOMETERS, THERMISTORS 2000-08-02 to 2000-09-30 TEXAS ASCII
NARSTO EPA Supersite (SS) New York Air Chemistry, Particulate Matter, and Meteorological Data GROUND STATIONS BAROMETERS, UV OZONE DETECTORS, PYRANOMETERS, HYGROMETERS, CHEMILUMINESCENCE, ION CHROMATOGRAPHS, ANEMOMETERS, THERMISTORS 2000-01-01 to 2006-01-01 NEW YORK ASCII
NARSTO EPA_SS_HOUSTON TEXAQS2000 Washburn Tunnel Air Quality Monitoring Data LABORATORY, GROUND STATIONS FOURIER TRANSFORM SPECTROMETERS, GAS CHROMATOGRAPHS, AEROSOL COLLECTORS, CHEMILUMINESCENCE, ION CHROMATOGRAPHS 2000-08-29 to 2000-09-01 TEXAS ASCII
NARSTO ICARTT NEAX 2004 DOE G-1 Air Chemistry, Aerosol, and Met Data AIRCRAFT BAROMETERS, UV OZONE DETECTORS, PYRANOMETERS, HYGROMETERS, CHEMILUMINESCENCE, ION CHROMATOGRAPHS, ANEMOMETERS, THERMISTORS 2004-07-24 to 2004-08-11 PENNSYLVANIA ASCII
NARSTO PAC2001 Langley Site Gaseous, Particle, and Meteorological Data GROUND STATIONS, METEOROLOGICAL STATIONS AETHALOMETER, TEMPERATURE PROBES, UV OZONE DETECTORS, GC-MS, TEOM, CHEMILUMINESCENCE, FLUORESCENCE SPECTROSCOPY, ION CHROMATOGRAPHS, HUMIDITY SENSORS, IR CO2 ANALYZER, PRESSURE SENSORS 2001-08-08 to 2001-09-02 BRITISH COLUMBIA, CONTINENT, EUROPE, WESTERN EUROPE, FRANCE ASCII
NARSTO PAC2001 Sumas Eagle Ridge Gaseous, Particle, and Meteorological Data GROUND STATIONS, METEOROLOGICAL STATIONS AETHALOMETER, UV OZONE DETECTORS, GC-MS, TEOM, CHEMILUMINESCENCE, FLUORESCENCE SPECTROSCOPY, TEMPERATURE SENSORS, ION CHROMATOGRAPHS, HUMIDITY SENSORS, IR CO2 ANALYZER, PRESSURE SENSORS 2001-08-13 to 2001-09-05 BRITISH COLUMBIA ASCII
NARSTO Pacific 2001 Air Quality Study (PAC2001) Slocan Park (SLPK) Slocan Park Site Gaseous, Partculate Matter (PM), and Meteorological Data GROUND STATIONS, METEOROLOGICAL STATIONS AETHALOMETER, TEMPERATURE PROBES, UV OZONE DETECTORS, GC-MS, TEOM, CHEMILUMINESCENCE, FLUORESCENCE SPECTROSCOPY, ION CHROMATOGRAPHS, HUMIDITY SENSORS, IR CO2 ANALYZER, PRESSURE SENSORS 2001-08-11 to 2001-09-01 BRITISH COLUMBIA ASCII
NARSTO SOS99 Nashville Tennessee Valley Authority (TVA) Surface Meteorology and Chemistry Data GROUND STATIONS, METEOROLOGICAL STATIONS NDIR GAS ANALYZER, UV OZONE DETECTORS, PYRANOMETERS, CHEMILUMINESCENCE, FLUORESCENCE SPECTROSCOPY, ANEMOMETERS, THERMISTORS 1999-06-15 to 1999-07-16 TENNESSEE, UNITED STATES OF AMERICA, NORTH AMERICA, CONTINENT ASCII
SHOWING 10 OF 131

Nitrogen Oxides Data Tools

No Results

Frequently Asked Questions

Earthdata Forum

Our online forum provides a space for users to browse thousands of FAQs about research needs, data, and data applications. You can also submit new questions for our experts to answer.

Submit Questions to Earthdata Forumand View Expert Responses

Earthdata
Forum