Skip to main content

C61 Aqua post safe-mode reprocessing of L1B, Atmosphere and selected Land products

Resolved Outage
Issued
Nov. 2, 2022
Resolved
Nov. 30, 2022

MODAPS is currently set to reprocess all C61 L1B, Atmosphere, and the Land LST MYD21 product suite, for the period 2022-04-17 (DOY 2022-107) thru 2022-07-26 (DOY 2022-207 included). This reprocessing will address the drift in the cross-talk correction for the PV-LWIR bands 27-30 that was noticed after the Aqua MODIS instrument came back from the last S/C and instrument safe-mode that lasted between 2022-03-31 (DOY 090) and 2022-04-14 (DOY 104). More details regarding this last safe-mode and the progression of events following that can be found (here.

The same L1B LUTs that resolves this drift in the PV-LWIR cross-talk, have been operational in the C61 forward processing stream, starting DOY 2022-208 (2022-07-27). The main impact from this cross-talk update is expected to be on the cloud and water vapor Atmosphere products. The MYD21 LST product is also expected to show differences of up to 0.5-1K, mainly over the vegetated areas. Users are requested to take note of this and start using the reprocessed versions of these products for any future studies.

Details

Last Updated

Nov. 4, 2022

Published

Nov. 13, 2026

Data Center/Project

Level-1 and Atmosphere Archive and Distribution System DAAC (LAADS DAAC)